Growatt SPH 3000-6000TL BL-UP are single-phase hybrid inverters. When paired with a low voltage battery, these inverters provide an uninterruptible power supply to a residence.Buy Growatt 5KW Single Phase Hybrid Inverter which is of high quality directly with low price.
SPH Growatt 5KW Single Phase Hybrid Inverter is used to store energy generated by the photovoltaic cell panels or energy from grid if it is allowed in the battery, also energy can be sent to power grid through SPH for self consumption or when Grid power is lost, SPH can be used as backup power.High quality Growatt 5KW Single Phase Hybrid Inverter residential solar storage system is the ultimate solution for reducing reliance on the grid, providing high-power generation with dual MPP trackers and the added security of a UPS function.
Residential Storage Inverter
SPH 3000-6000TL BL-UP
3-6kW | Hybrid | UPS
● SPH 3000 TL BL-UP
● SPH 3600 TL BL-UP
● SPH 4000 TL BL-UP
● SPH 4600 TL BL-UP
● SPH 5000 TL BL-UP
● SPH 6000 TL BL-UP
* Smart load management via dry contact
* UPS function, 10ms transition
* Scalable system configuration
* VPP interface ready
* Remote smart O&M
* 2 DC/AC Ratio
These single phase residential hybrid inverters have an outstanding efficiency up to 97.6%. They include an LCD & LED display with touch keys as well as a DC switch.The inverter also comes with built-in MPPT (Maximum Power Point Tracking) technology to ensure maximum power production from the solar panels. Additionally, Growatt 5KW Single Phase Hybrid Inverter has a user-friendly interface for easy monitoring and control of the energy system.
Technical Parameters
Datasheet | SPH3000TL BL-UP | SPH3600TL BL-UP | SPH4000TL BL-UP | SPH4600TL BL-UP | SPH5000TL BL-UP | SPH6000TL BL-UP |
Input data(PV) | ||||||
Max. recommended PV power (for module STC) | 6000W | 7200W | 8000W | 9200W | 10500W | 11200W |
Max. DC voltage | 550V | |||||
Start voltage | 120V | |||||
MPP voltage range | 120-550V/360V | |||||
No. of MPP trackers | 2 | |||||
No. of PV strings per MPP tracker | 1 | |||||
Max. input current per MPP tracker | 13.5A | |||||
Max. short-circuit carent per MFP tracker | 16.5A | |||||
Output data(AC) | ||||||
AC nominal power | 3000W | 3680W | 4000W | 4600W | 5000W | 6000W |
Max. AC apparent power | 3000VA | 3680VA | 4000VA | 4600W | 5000VA | 6000VA |
Nominal AC voltage (range) | 230V/(18(Mic-270Vac) | |||||
AC grid frequency (range) | 50Hz/60Hz (45Hz-55Hz/55Hz-65Hz) | |||||
Max. output current | 22A 22A | |||||
Adjustable power factor | 0.8leading.. .0,8lagging | |||||
THDi | <3% | |||||
AC grid connection type | Single phase | |||||
Battery data (DC) | ||||||
Battery voltage range | 42-59V | |||||
Max charging and dschaging curent | 85A 85A | |||||
Continuous charging and discharging power | 3000W | 3680W | 4000W | 4000W | 4000W | 4000W |
Type of battery | Lilhium /Lead-acid | |||||
Backup power(AC) | ||||||
Max. AC output power | 3000W | 3680W | 4000W | 4000W | 4000W | 4000W |
Max. output current | 17.4A | |||||
Nominal AC output voltage | 230Vac | |||||
Nominal AC output frequency | 50/60HZ | |||||
THDv | <3% | |||||
Switch time | <10ms | |||||
Efficiency | ||||||
MAX. efficiency | 97.20% | 97.20% | 97.30% | 97.40% | 97.50% | 97.60% |
European efficiency | 97% | 97% | 97.10% | 97.10% | 97. 20% | 97.20% |
MPPT efficiency | >99.5% | |||||
Protection devices | ||||||
DC switch | Yes | |||||
DC reverse polarity protection | Yes | |||||
AC/DC surge protection | Yes | |||||
Battery reverse protection | Yes | |||||
AC short-circuit protection | Yes | |||||
Ground fault monitoring | Yes | |||||
Grid monitoring | Yes | |||||
Anti-islanding protection | Yes | |||||
Residual-current monitoring unit | Yes | |||||
Insulation resistance monitoring | Yes | |||||
General data | ||||||
Dimensions (W/H/D) | 458/565/188mm | |||||
Weight | 31kg | |||||
Operating temperature range | -25℃... +60°C | |||||
Nighttime power consumption | < 10W | |||||
Topology | Transformerless | |||||
Cooling | Natural | |||||
Protection degree | IP65 | |||||
Relative humidity | 0-100% | |||||
Altitude | 2000m | |||||
PV DC Connection | H4/MC4(Optional) | |||||
Battery DC Connection | OT Terminal | |||||
AC connection | Connector | |||||
Display | LCD+LED | |||||
lnterfaces:RS485/CANAJSB | Yes | |||||
Monitor: RF/WIFI/GPRS | Optional | |||||
Waranly: 5 years /10 years | Yes/Optional |
Leading Functions
- UPS function, 10ms transition
- Scalable system available
High Yields
- DC/AC ratio up to 2.0
- Dual MPP trackers
System Flexibility
- Support lithium and lead-acid battery
- VPP interface ready
- Smart load control via dry contact