A newly designed solar and energy storage hybrid inverter,capable to install in on-grid solar,off-grid solar and back-up systems.The following is the introduction of high quality LXP 3KW Single Phase Hybrid Inverter, hoping to help you better understand it.
LXP 3KW Single Phase Hybrid Inverter enables a programmable and scheduled smart solar energy storage system to help increase your solar energy self-consumption rate,protect your home appliances from grid shortage,and balance your energy usage strategy to save energy bill. High quality LXP 3KW Single Phase Hybrid Inverter can meet many applications, if you need, please get our online timely service about LXP 3KW Single Phase Hybrid Inverter.
Solar Hybrid Inverter
LXP Hybrid 3-6k
LXP3K
LXP3.6K
LXP4K
LXP4.6K
LXP5K
LXP6K
Solar Hybrid Inverter Performance
- Hybrid solar inverter Intelligent working modes
- Stronger UPS
- Easy to use with battery
- IP65, indoor & outdoor use
- Advanced Parallel, up to 60kW
- Plug & Play, seamless switching under
- Light, fast & easy installation
- Free & handy monitoring on mobile / PC
- The best hybrid solar inverter work with utilities to intelligently manage the battery and save bills
Technical Parameters
Solar | LXP3K | LXP3.6K/4k | LXP4.6K/5K | LXP6K |
Max. DC Input Power | 6600W | 7000W | 8000W | 8000W |
Nominal DC Input Voltage | 360V.d.c | 360V.d.c | 360V.d.c | 360V.d.c |
DC Input Voltage Range | 100 - 550V.d.c | 100 - 550V.d.c | 100 - 550V.d.c | 100 - 550V.d.c |
MPPT Voltage Range | 100 - 500V.d.c | 100 - 500V.d.c | 100 - 500V.d.c | 100 - 500V.d.c |
Start-up Voltage | 120V.d.c | 120V.d.c | 120V.d.c | 120V.d.c |
MPPT Number | 2 | 2 | 2 | 2 |
Max. DC Input Current | 13A/13A | 13A/13A | 13A/13A | 13A/13A |
Battery | ||||
Compatible Battery Type | Lithium-ion/Lead-Acid | Lithium-ion/Lead-Acid | Lithium-ion/Lead-Acid | Lithium-ion/Lead-Acid |
Nominal Battery Voltage | 48V.d.c | 48V.d.c | 48V.d.c | 48V.d.c |
Battery Voltage Range | 40 - GOV.d.c | 40 - GOV.d.c | 40 - GOV.d.c | 40 - GOV.d.c |
Max. Charge/Discharge Current | 66A/66A | 66A/66A | 80A/80A | 80A/80A |
Max. Charge/Discharge Power | 3600W/3600W | 3600W/3600W | 4000W/4000W | 4000W/4000W |
Charging Curve | 3 stages | 3 stages | 3 stages | 3 stages |
Max. Charge Voltage | 59V | 59V | 59V | 59V |
Capacity of Battery | 2-20kWh | 2-20kWh | 2-20kWh | 2-20kWh |
Grid | ||||
Nominal AC Output Power | 3000W | 3600W/4000W | 4600W/5000W | 6000W |
Max. AC Output Power | 3000VA | 3600VA/4000VA | 4600VA/5000VA | GODOVA |
Max. AC Output Current | 15A | 16A/20A | 25A | 26A |
Nominal AC Voltage | 230V.a.c | 230V.a.c | 230V.a.c | 230V.a.c |
AC Voltage Range | 180 - 270V.a.c | 180 - 270V.a.c | 180 - 270V.a.c | 180 - 270V.a.c |
Nominal AC Frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
AC Frequency Range | 45-55Hz/55-65Hz | 45-55Hz/55-65Hz | 45-55Hz/55-65Hz | 45-55Hz/55-65Hz |
Power Factor | Adjustable 0.8 overexcited to 0.8 underexcited | |||
THDI | <3% | <3% | <3% | <3% |
EPS | ||||
UPS Max. Output Power without So Lar | 3000W | 3600W/4000W | 4000W | 4000W |
UPS Max. Output Power with Solar | 3000W | 3600W/4000W | 5000W | 6000W |
UPS Nominal Output Voltage | 230V.a.c | 230V.a.c | 230V.a.c | 230V.a.c |
UPS Nominal Output Frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
UPS Nominal Output Current | 13A | 15.6A/17.4A | 17.4A | 17.4A |
Peak Power Without Solar | 4500W, 30s | 4500W, 30s | 4500W, 30s | 4500W, 30s |
THDV | <5% | <5% | <5% | <5% |
Switching Time | Typical 0.01s | Typical 0.01s | Typical 0.01s | <0.01s |
Efficiency | ||||
Europe Efficiency | 97.5% | 97.5% | 97.5% | 97.5% |
Max. Efficiency | 97.9% | 97.9% | 97.9% | 97.9% |
Battery Charge/Discharge Efficiency | 94.5% | 94.5% | 94.5% | 94.5% |
Protection | ||||
Reverse Polarity Protection | Yes | Yes | Yes | Yes |
Over Current/Voltage Protection | Yes | Yes | Yes | Yes |
Anti-islanding Protection | Yes | Yes | Yes | Yes |
AC Short-ciruit Protection | Yes | Yes | Yes | Yes |
Leakage Current Protection | Yes | Yes | Yes | Yes |
Ground Fault Monitoring | Yes | Yes | Yes | Yes |
Grid Monitoring | Yes | Yes | Yes | Yes |
Ingress Protect Degree | IP65 / NEMA4X | IP65 / NEMA4X | IP65 / NEMA4X | IP65 / NEMA4X |
DC Switch | Yes | Yes | Yes | Yes |
General | ||||
Dimensions (W/H/D) | 455 / 476 (565) / 181 | 455 / 476 (565) / 181 | 455 / 476 (565) / 181 | 455 / 476 (565) / 181 |
Weight | 20 kg | 20 kg | 20 kg | 20 kg |
Topology | TranformerLess (solar), HF (Battery) | |||
Cooling Concept | Natural Convection | Natural Convection | Natural Convection | Natural Convection |
Relatively Humidity | 0-100% | 0-100% | 0-100% | 0-100% |
Operating Temperature Range | -25 - 60 | -25 - 60 | -25 - 60 | -25 - 60 |
Altitude | <2000m | <2000m | <2000m | <2000m |
Noise Emission | <25dB | <25dB | <25dB | <25dB |
Standby Consumption | <5W | <5W | <5W | <5W |
Display & Communication Interfaces | LCD, RS485, Wi-Fi, | LCD, RS4B5, Wi-Fi, | LCD, RS4B5, Wi-Fi, | LCD, R5485, Wi-Fi, |
CAN | CAN | CAN | CAN |
Solar Hybrid Inverter Application
System Connection
A newly designed solar and energy storage hybrid inverter, capable to install in on-grid solar, off-grid solar and back-up systems. LXP Hybrid enables a programmable and scheduled smart solar energy storage system to help increase your solar energy self-consumption rate, protect your home appliances from grid shortage, and balance your energy usage strategy to save energy bill.
Working Modes
LXP hybrid inverters support variable working modes
Self consumption mode: the solar hybrid inverter will first use the solar energy for the house load first, the left solar power will be used to charge the battery. After the hybrid inverter’s battery is charged, the solar energy can be fed into the grid.
Force charge and discharge mode: inverter will charge or discharge battery according to the time users set.
Charge first mode: the solar energy collected by the hybrid inverter will be used to charge the battery first. then take family load and at last feed into grid. This mode of the hybrid inverter is suitable for areas with unstable power supply from the grid.